Conductivity is used to monitor chemical concentration and control it by adjusting the ratio of water to acid or caustic. Chemical concentration control applications can be hard on conductivity sensors as high concentrations of acid or caustic can corrode the metal electrodes. In many concentration control applications, such as cleaning solutions, the acid or caustic solution is recycled back to the concentration control mixing tank for re-use. This can lead to the accumulation of solids in the solution that can coat or plug the electrodes on contacting conductivity sensors, resulting in an unreliable measurement. The Rosemount™ 228 Toroidal Conductivity Sensor is an excellent solution for most concentration control applications due to its superior corrosion and coating resistance compared to contacting conductivity sensors.
Rosemount 1058 이중 채널 트랜스미터는 광범위한 산업, 도시 및 상업 응용 분야에서 정확한 액체 분석 측정을 제공합니다. pH/ORP 센서, ISE, 유량, 전류, 전도도 센서(접촉 및 트로이달), 탁도 센서 및 전류 측정 센서(용존 산소, 염소 및 오존) 입력을 비롯하여 디지털 및 아날로그 센서에 대한 다중 매개변수 액체 분석을 제공하는 4선식 구동 장치입니다.