다상
아무리 까다로운 현장에서도 유연성을 달성하고 정확한 유량 측정 기능을 제공
전 세계의 점점 더 많은 응용 분야 및 현장 조건에서 분리하지 않고도 수행할 수 있는 다상 유량의 고품질 측정 작업이 필요합니다.
Emerson이 제조한 다상 유량계를 선택하면 모든 다상 유량 응용 분야에서 확실하고 안정적인 측정 성능을 보장할 수 있습니다. 30년이 넘는 현장 경험과 글로벌 입지를 통해 고객은 이미 잘 알고 신뢰하는 공급업체로부터 측정 계기와 필요한 지원을 모두 확보할 수 있습니다.
Introducing the Roxar 5726 Multiphase Transmitter, the new electronics hardware platform for the Roxar 2600 Multiphase Flow Meter, offering high measurement resolution and processing power for improved autonomy and data analytics.
With Rapid Adaptive Measurement, the meter flow computer conducts parallel computation using multiple calculations modules. Each calculation module runs independently, and modules can be enhanced or replaced in the future without affecting the rest of the software structure.
The Roxar 2600 Multiphase Flow Meter powered by the 5726 Multiphase Transmitter offers future-ready reliability, allowing operators to easily adopt new enhancements without costly replacements. It ensures efficient, long-term performance, adapting to evolving needs and maximizing asset lifecycle value.
The updated compact hardware arrangement of the Roxar 2600 Multiphase Flow Meter powered by the 5726 Multiphase Transmitter provides straight forward, effective installation, reduced instrumentation footprint and simplified field cabling requirements.
As oil and gas operators worldwide adjust their production methodologies and target more challenging reservoirs, the flow profiles from the wells are becoming significantly more varied and dynamic, and the demands on the instrumentation increase. To address these demands in multiphase measurement, Emerson restructured how the Roxar 2600 Multiphase Flow Meter now processes sensor signals, self-verifies calculation modules and automatically selects the best-suited measurement modes at any given moment. This ensures that operators receive reliable oil, water and gas measurement, without the need for frequent reconfiguration, even in the most challenging field conditions.
Layer detection and compensation features are built into the embedded software of the Roxar 2600 Multiphase Flow Meter to protect the integrity, reliability and robustness of the measurement results provided by the Roxar 2600 Multiphase Flow Meter.
At different pressures and temperatures, the interaction between the oil, water and gas phases of the multiphase flow constantly changes. An extensive PVT calculation engine is now embedded within the Roxar 2600 Multiphase Flow Meter flow computer software, which supports several equations of state models and property libraries, ensuring volumes are correct as pressures and temperatures change.
The adaptive density measurement feature has been introduced within the Rapid Adaptive Measurement embedded software for the Roxar 2600 Multiphase Flow Meter, to ensure performance with the highest possible stability and reliability in flow regimes with high gas fractions, or when the flow is slugging and sees such conditions periodically.
유정의 성능 최대화는 적절한 기술을 보유한 인력에 달려 있습니다.